CISA Flags Yokogawa CENTUM VP Vulnerabilities Enabling Arbitrary Code Execution in Industrial Control Systems

CISA issued an Industrial Control Systems Advisory (ICSA-26-057-09) on February 26, 2026, identifying six critical vulnerabilities (CVE-2025-1924, CVE-2025-48019 through CVE-2025-48023) in Yokogawa CENTUM VP R6 and R7 Vnet/IP Interface Packages at versions â‰ĪR1.07.00. Successful exploitation permits arbitrary code execution, denial-of-service, or software stack termination. The advisory does not specify patch availability or mitigation timeline.
AI synthesis, editor-reviewed · 1 source · February 26, 2026 · Confidence high (primary document)

This vulnerability forces a procurement decision in the critical infrastructure supply chain: operators must either accelerate patch deployment (creating a 6-12 month validation bottleneck at integrators like Emerson and Honeywell) or fund replacement of affected CENTUM VP instances with competing platforms (ABB, Siemens, Rockwell).

The delay directly compresses capital budgets for other industrial modernization, shifting FY2026-2027 spending from greenfield digital transformation into reactive remediation.

If patches remain unavailable beyond Q2 2026, operators of aging CENTUM VP R6 systems in power and water treatment will face regulatory pressure to justify continued operation, potentially forcing early retirement of otherwise serviceable infrastructure.

WHY IT MATTERS

CENTUM VP is the standard process control platform across U.S. petrochemical, refining, power generation, and water treatment infrastructure.

Arbitrary code execution in the network interface layer exposes critical infrastructure operators to remote takeover without authentication complexity — a direct path to sabotage or espionage. Operators of affected systems face a binary choice: patch immediately (risking production downtime during validation) or operate known-vulnerable systems (accepting adversary access).

The absence of patch details in the CISA advisory suggests either patches are not yet available or deployment is still in testing, extending the exposure window.

This creates immediate procurement pressure on site integrators and control system vendors to accelerate patch deployment and validation cycles, and forces critical infrastructure operators to prioritize CENTUM VP system isolation or replacement in FY2026 capital plans.

WHAT THIS DOESN’T TELL US

The advisory does not state: (1) whether Yokogawa has released patches or a patch timeline; (2) whether any of these CVEs have been exploited in the wild; (3) the estimated number of CENTUM VP R6/R7 installations in U.S. critical infrastructure; (4) whether the vulnerabilities require network access...

Sources: CISA (Cybersecurity & Infrastructure Security Agency)